Parameter | Description |
Name | Name of the Unit. |
Description | Description of the Unit. |
Template name | Name of the Unit Type Template. |
Template version | Version of the Unit Type Template. |
Tickets on roll | Number of tickets on roll. Valid values between 1-3000. Default value is 2000. |
Parameter | Description |
Name | Name of the Unit. |
Description | Description of the Unit. |
Type name | Name of the Unit Type. |
Type description | Description of the Unit Type. |
Unit id | Identification code of the Unit. |
Touch Application | Name of Touch Application (created in the Surface Editor application). For more information see the Administrator’s Guide. |
Date format on ticket | From the drop-down list, select the wanted date format. Available formats are: YYYY-MM-DD; DD-MM-YY; MM-DD-YY; and Day Month Year. |
Time format on ticket | From the drop-down list, select the wanted time format. Available formats are: HH:MM; HH:MM am/pm; HH:MM:SS; and HH:MM:SS time zone (for example CEST). |
Surface custom parameters | Which custom parameters should be available on the ticket. The following parameters and strings to use in the Surface Editor application are available: • Waiting customers • Current waiting time • Branch name • Tickets left Mark several of them by holding down Ctrl while clicking on them |
Button delay | This is the minimum time that must elapse after a Customer has pressed the button and until the next Customer can get a ticket. Max: 60 seconds. Min: 0 seconds. |
Tickets on roll | Number of tickets on roll. |
Low ticket alarm | The number of tickets in the printer when the alarm is activated. The ticket counter is restarted when the paper is fed into the printer mechanism. |
Device Controller | From the drop-down list, select which Device Controller should be used. |
Parameter | Description |
Default name | Default name of the Unit. |
Description | Description of the Unit. |
Unit Identifiers | The two columns of the table are: • Name - Name of the unit, by default the name of the unit plus a sequential number, for example WebReception 5 or WebServicePoint 2. Can be changed to anything, so long as the name is unique, within the Branch. • Logic Id - An ID used in the connectors. The Logic Id continues with the next number in the sequence of the auto generated ID's within the Unit Type (e.g. Service Points, Entry Points, or Presentation Points). The number can be changed to anything, in the range of 1-9999, as long as it is unique within the Service Point, Entry Point, or Presentation Point. |
Unit id | Identification code of the Unit. |
IP address | IP address of the ticket printer. |
Touch Application | Name of Touch Application that is used. |
Widgets enabled | States whether or not the use of widgets is enabled for this touch application. |
Device Controller | Name of Device Controller that is used. |